Peer Reviewed Open Access

This paper is reviewed in accordance with the Peer Review Program of IRA Academico Research


Study of the Optimum Thermal Insulation Thickness of a Calorimeter Wound with Linen Insulation

Mame Fadiamé THIAM, Seydou FAYE, Babou DIONE
Abstract
In this article, the object of the study is focused on the influence of local insulating materials in the design of a calorific model for the conservation of hot water for a fixed period. The short hollow cylinder is wound with thermal insulation flax between the two walls of the cylindrical device to insulate the interior temperature. The objective of this study is to see the behavior of the thermal resistance of the material as a function of the insulation thickness. The cylinder is modeled by applying the transient analytical method with the heat equation. This analytical resolution of the thermal equation makes it possible to determine the detailed expression of the thermal resistance but also to visualize the evolution curves of this resistance according to the thickness of the insulation under the influence of the contact resistance thermal and heat exchange coefficient on the outside cylinder wall. The results obtained show that the optimum insulation thickness of linen at a temperature of 90 °C is 3.7 cm under the influence of the thermal resistance of the material and 4 cm under the influence of the exchange coefficients thermal.
Keywords
Analytical method, transitional system, contact thermal resistance, coefficient of thermal exchange
Full Text:
PDF
References

Seguin, J. P. Gosse, Dispositif de mesure calorimétrique des pertes dans les condensateurs de puissance, Journal de Physique III France, (1997) 321-336. [25] E. https://doi.org/10.1051/jp3:1997125

A. GUREL, A. DASDEMIR. Economical and environmental effects of thermal insulation thickness in four different climatic regions of Turkey. International Journal of Renewable Energy Research. Vol.1, No.1, pp.1-10, 2011.

Cheikh Tidiane Sarr, Issa Diagne, Mamadou Lamine Sow, (2009) « Caractérisation des isolants thermiques cylindriques par une méthode analogique : Application au Kapok » J. Sci Vol. 9, N° 3, 32–46.

D. CHRISTEN –U. BADSTUEBNER – J. BIELA – J.W. KOLAR – Calorimetric power loss measurement for highly efficient converters - The 2010 International Power Electronics Conference (IPEC), pp. 1438 – 1445, 2010. https://doi.org/10.1109/IPEC.2010.5544503

A. SALEH, M. MOSA. Analysis of control strategies and simulation of heating systems using Simulink/ Matlab potential-Journal of Thermal Engineering. Vol. 2, No. 5, Oct 2016. pp. 921-927. https://doi.org/10.18186/jte.97874

Y. TRAORE, I. DIAGNE, C. SARR, M. S. OULD BRAHIM, A. K. DIALLO, H. LY DIALLO, AND G. SISSOKO. Influence of thermal exchange coefficient on the heat retention rate of a concrete wall contiguous to a thermal insulation tow-plaster. ARPN Journal of Engineering and Applied Sciences. Vol. 11, N° 5, 2016.

LEFEBVRE, G. (1989). Caractérisation de l’inertie thermique d’un bâtiment par analyse modale. Revue general de thermique, 28:501–51.

JAKOSKY, B. M., M. T. Mellon, H. H. Kieffer, P. R. Christensen, E. S. Varnes, and S. W. Lee (2000), The thermal inertia of Mars from the Mars global surveyor thermal emission spectrometer, J. Geophys. Res., 105, 9643 – 9652. https://doi.org/10.1029/1999JE001088



©IRA Academico Research & its authors
This article is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License. This article can be used for non-commercial purposes. Mentioning of the publication source is mandatory while referring this article in any future works.